Portable Survey Meters
FRISKERS
One-handed frisking for alpha and beta contamination. The operation of the Model is kept simple through the use of just two to three buttons that are strategically placed for one-handed operation.
The Model 26 series may also be ordered with a standard 3 mm (1/8 in.) plug, mono headphone jack to better monitor the instrument’s audible output in noisy environments. |
TYPES OF FRISKERS
Model 26
Basic Lightweight Design Simplifies Frisking Model 26-1 Units: cps, cpm, µSv/h, mR/hr, dpm, Bq Model 26-1 DOSE Integrated Frisker with Dose Equivalent Filter Model 26-2 Integrated Frisker with Timed Frisk Units: cps, cpm Model 26-3 Dead-Time Correction Allowing Gamma Measurements up to 1000 mR/hr (1999 µSv/h) |
General Purpose
Available in both analog and digital, durable, lightweight detecting instruments are designed for general purposes of a digital survey meter. The instrument is customised for detection of various radiation such as alpha, beta, gamma & neutron. Some of which even has an internal data logging capability.
Available in for single &/or multiple radiation detection with wide and easy to read digital screens to help ease your choice. Model 3XXX (3000, 3014) series can also be used as dataloggers. |
TYPES OF GENERAL PURPOSES
|
Computerised
A computer is required to read data from the instruments. Ludlum offers a ruggedized computer as an option, or the customer may provide their own computer. LUDLUM also provides the necessary software options. The computerised survey meters are best used for large scale detection & recording purposes.
|
TYPES OF COMPUTERISED
Model 4404-16 Series
Geo-Exploration Monitor Large NaI Scintillator Detector Google Earth™ Compatible Files Model 4600 Series Multi-Detector Benchtop Counter 1 to 12 Channels Single Channel Analysis User-Adjustable Parameters |
Geiger counter
A Geiger counter (also known as a Geiger–Müller counter) is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental physics and the nuclear industry.
|
GEIGER COUNTERS
Model 3005
Auto-Ranging Digital Meter Internal Energy-Compensated GM Detector Range: 0.001 to 50 mSv/h Includes Data Logging Capability\ Model 5 5-Range Analog Meter Two Internal Energy-Compensated GM Detectors Range: 0 to 20 mSv/h (0 to 2000 mR/hr) Model 6 3-Range Analog Meter Internal Energy-Compensated GM Detector Range: 0 to 10 mSv/h (0 to 1000 mR/hr) |
Intrinsically Safe
Modelled after best selling Model 3, LUDLUM continued the series that are designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres.
The Model 25-IS and Model 25-IS-1 are intrinsically safe versions of the Model 25 Series Personal Radiation Monitors. They are small, rugged devices designed to warn emergency response personnel of any dangerous radiation fields that they may encounter, and are certified for use in areas where explosion safety is a concern. |
TYPES of INTRINSICALLY SAFE
Model 3-IS 4-Range Analog Meter Supports Select GM & Scintillator Detectors Model 3-IS-1 Intrinsically Safe Gamma Ratemeter 4-Range Analog Ratemeter Built-in Energy Compensated GM Detector Model 25-IS Series Intrinsically Safe Personal Radiation Monitor Water Resistant Design 6000 Hour Battery Life |
Ion Chambers
The Ludlum Model 9DP Series pressurized ion chamber meter provides highly sensitive measurements of exposure and exposure rate. It can simultaneously display the exposure rate and integrated value, or the highest rate seen by the instrument. Contact us for the HAZMAT Series that provides ICRU-Based Ambient Dose Measurements.
The Model 9-4 & 9-3 uses rugged air ionisation chamber for performing beta-gamma dose rate measurements over a five-decade spanning over a wide radiation range. The chamber wall (including the instrument case) is 1000 mg/cm2. A 1000 mg/cm2 retractable beta shield allows beta measurement with a 7 mg/cm2 window. The Ludlum Model 9-7 Ion Chamber Display Unit is a digital readout and control unit that can be attached to any compatible ion chamber (sold separately). This instrument provides remote monitoring in high-range beta and gamma fields. |
TYPES of ION CHAMBERS
Model 9DP 0 to 50 mSv/h (0 to 5 R/hr) Range with μR/hr Sensitivity Chamber Pressure: 9 atm (122 psig) Model 9DP-1 Special Design for Measuring Pulsed Fields 2 µSv/h to 500 mSv/h (200 µR/hr to 50 R/hr) Operating Range Chamber Pressure: 2.5 atm (22 psig) [Non-HAZMAT] Model 9-3 5-Range Analog Meter Range: 0 to 500 mSv/h (0 to 50 R/h) Temperature Compensated Model 9-4 5-Range Analog Meter Range: 0 to 500 mSv/h (0 to 50 R/hr) Temperature & Pressure Compensated Model 9-4 RF RF Immunity 5-Range Analog Meter Range: 0 to 500 mSv/h (0 to 50 R/hr) Temperature & Pressure Compensated Model 9-7 High Range Ion Chamber Survey Meter Digital Meter Display Range: 0 to 19.99 kR/hr 3 Available Detectors |
Isotope Identifiers
LUDLUM provides isotope identifier with an internal/external NaI/LaBr detector provides end users like first responders a simple tool to quickly locate any abnormal levels of radioactivity and accurately identify the isotopes present.
The 700-Series employs time-slicing and patented Quantum Compression Conversion (QCC) technology that delivers improved energy resolution, real-time background subtraction, and the highest degrees of sensitivity. Trace amount of 40K are embedded to provide gain stabilisation and self-calibration. All captured spectra data are stored to a removable compact flash card in ANSI N42.42 standard format. These units have a trace amount of 40K embedded to provide gain stabilisation and self-calibration. |
TYPES of ISOTOPE IDENTIFIERS
|
MICROR / MICROSV
Available in digital & analog options, LUDLUM provides simple, user friendly & portable options in the microR / microSv range. Different detector options are also available. Best used for detecting very low levels of X-rays, gamma rays or other radiation waves.
|
TYPES of MicoR/ MicroSv
|
Extended microR / microSv
Available in digital & analog options, LUDLUM provides simple, user friendly & portable options in the microR / microSv range. Different detector options are also available. Best used for detecting very low levels of X-rays, gamma rays or other radiation waves.
|
TYPES of EXTENDED MICROR/MICROSV
Model 3006
External 15.2 x 2.5 cm (6 x 1 in.) Plastic Scintillator Detector Attached to 118 cm (46.5 in.) Pole Sensitivity (137Cs): 2500 cps per µSv/h (1500 cpm per µR/hr) Model 193-6 External 15.2 x 2.5 cm (6 x 1 in.) Plastic Scintillator Detector Attached to 122 cm (48 in.) Pole Sensitivity (137Cs): 2500 cps per µSv/h (1500 cpm per µR/hr) Range: 0 to 10 µSv/h (0 to 1000 µR/hr) Model 30-6 Model 30-Series Digital Meter External 15.2 x 2.5 cm (6 x 1 in.) Plastic Scintillator Detector Attached to 173 cm (68 in.) Pole Sensitivity (137Cs): 2500 cps per µSv/h (1500 cpm per µR/hr) |
Neutron Meters
LUDLUM provides portable neutron meters with a cadmium-located polyethylene sphere surrounding a 3He detector of various sizes (according to the purpose of the meter).
The neutron detector is designed to detect thermal and fast neutrons . Neutrons are detected indirectly through nuclear reactions, which result in energetically charged particles. |
TYPES of NEUTRON METERS
|
Pocket-SizeD
LUDLUM provide different variation of the pock-sized survey meters of the Model 2401 Series that is targeted for very specific types of radiation detection (i.e. gamma, alpha, beta, x-ray, etc)
Most of the Model 2401 Series are 3-Range Analog Meters, with the only exception of Model 2403. |
SPECIFICATIONS
|
Stretch Scopes
Stretch Scopes are designed to survey areas for various radiation while maintaining distance from potentially high radiation fields. One of the design includes external detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types of instruments. The meter body is made of durable, high-impact plastic with splash-resistant construction for outdoor use.
The other design includes having a one-size detector with a built-in telescoping Stainless Steel Pole that is extendable up to 3.6m (12ft). A clip-on adjustable shoulder strap is included. The instrument handle may be removed, thereby reducing the collapsed length from 105.9 cm (41.7 in.) to 92 cm (36.2 in.) for easier transport and storage of the instrument. |
SPECIFICATIONS
Model 3078 Series
Two External Energy-Compensated GM Detectors Available w Internal Energy-Compensated GM Detector Range: 1 µSv/h to 10 Sv/h (0.1 mR/hr to 1000 R/hr) Model 79 Energy-Compensated GM Detector Range: 10 µSv/h to 10 Sv/h (1 mR/hr to 1000 R/hr) Model 79/1 CsI(Tl) Scintillator Detector Range: 0.01 µSv/h to 500 µSv/h (1 µR/hr to 50 mR/hr) Model 79/2 Internal Energy-Compensated GM Range: 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr) Model 78 Analog + Digital Meter 2 Energy-Compensated GM Detectors Range: 0.1 mR/hr to 1000 R/hr Model 78-1 Analog + Digital Meter 2 Energy-Compensated GM Detectors Range: 0.1 µSv/hr to 9999 mSv/hr Model 78-6 Analog + Digital Meter NaI(Tl) Scintillator Detector Range: 0.01 to 50 µSv/h (1 to 5000 µR/hr) Model 78-9 Analog + Digital Meter Pancake GM Detector |
RELATED PRODUCT
*Pictures shown above are for reference only. Actual product may differ slightly.
*Some products may not be available in all countries. Please contact us for further information and clarification. |
Don't have what you are looking for?