High Speed Fixed Gain

Model

3-dB Bandwidth (DC ...) Noise Current [/√Hz] Transimpedance (Gain) Rise/Fall Time Max. Source Capacitance
HCA-1M-1M 1 MHz 270 fA 1 x 106V/A 350 ns 50 pF
HCA-1M-1M-C 1 MHz 3.5 pA 1 x 106V/A 350 ns 2 nF
HCA-2M-1M 2 MHz 340 fA 1 x 106V/A 180 ns 25 pF
HCA-2M-1M-C 2 MHz 3.5 pA 1 x 106V/A 180 ns 1 nF
HCA-4M-500K 4 MHz 490 fA 5 x 105V/A 90 ns 15 pF
HCA-4M-500K-C 4 MHz 3.5 pA 5 x 105V/A 90 ns 500 pF
HCA-10M-100K 10 MHz 1.1 pA 1 x 105V/A 35 ns 15 pF
HCA-10M-100K-C 10 MHz 3.5 pA 1 x 105V/A 35 ns 150 pF
HCA-20M-100K-C 20 MHz 3.5 pA 1 x 105V/A 18 ns 50 pF
HCA-40M-100K-C 40 MHz 3.7 pA 1 x 105V/A 10 ns 30 pF
HCA-100M-50K-C 100 MHz 3.8 pA 5 x 104V/A 3.5 ns 20 pF*
HCA-200M-20K-C 200 MHz 4.9 pA 2 x 104V/A 1.9 ns 8 pF*
HCA-400M-5K-C 400 MHz 21 pA 5 x 103V/A 1 ns 10 pF*
Output voltage ±1.5 V, @ 50 Ω load. Offset adjustable by trimpot. Output short-circuit protected. Adjustable bias-output (-12 V ... +12 V) for biasing photodetectors.  A mating connector is provided with the device. Optional power supply PS-15 available. For further information please view the datasheet.

NOTE: The maximum detector capacitance listed above means that up to this value the specified 3dB-bandwidth (±15 %) is guaranteed. Larger capacitances are also possible, but will slightly influence the bandwidth and frequency response.

* For the ultra fast models HCA-100M-50K-C, HCA-200M-20K-C and HCA-400M-5K-C a reduction in bandwidth up to 25 % of the nominal values might occur if the source capacitance reaches the above noted maximum source capacitance values. Especially for these models short cables at the input and the use of low capacitance sources is of major importance. 
​*Pictures shown above are for reference only.  Actual product may differ slightly.  
**Some products may not be available in all countries. Please contact us for further information and clarification.

Not what you are looking for?
​Search Here.​
Alternatively, please contact us for more information.
Contact Us

    subscribe to OUR newsletters

Subscribe

sitemap

About Us
Our Services
Products
News & Events​​
​
ANALYTICAL TECHNOLOGIES PTE LTD
​
50 Ubi Avenue 3 #05-08 Frontier Building
Singapore 408866
Tel : +65-67468068
Fax : +65-67460661

Email:  singapore@analytical-online.com
​​
© COPYRIGHT 2020. ALL RIGHTS RESERVED.
  • Products
    • BioTechnologies
    • Cryogenics
    • Deposition Systems
    • Imaging
    • Lasers
    • Wafer Probing
    • Pharmaceutical Testing Apparatus
    • Radiation Detection & Monitoring
    • Spectroscopic System
    • Supporting Instrument & Accessories
    • Surface Characterisation
  • News
  • Instrument demo
  • Customisation
  • Contact Us